Northwire Canada EditionWednesday, November 11, 2026
Northwire
⌕
Gold 4,030.20 −2.0% Silver 51.23 −2.8% Copper 6.27 −1.2% Oil 86.04 −0.9% Palladium 1,024.00 +0.2% NVX 0.910 +0.0% MSR 0.435 +0.0% ELE 22.85 −4.0% ALS 53.01 −2.2% APM 5.13 −6.6% AVL 5.46 −5.4% NG 8.84 −9.0% ATY 0.220 −2.2% CN 0.125 −10.7% PMET 3.22 −4.2% ITH 1.99 −11.6% VMET 12.33 −6.9% ABX 56.41 −5.6% PUR 0.370 +8.8% SCY 0.085 +6.2% AUMN 0.300 +7.1% Gold 4,030.20 −2.0% Silver 51.23 −2.8% Copper 6.27 −1.2% Oil 86.04 −0.9% Palladium 1,024.00 +0.2% NVX 0.910 +0.0% MSR 0.435 +0.0% ELE 22.85 −4.0% ALS 53.01 −2.2% APM 5.13 −6.6% AVL 5.46 −5.4% NG 8.84 −9.0% ATY 0.220 −2.2% CN 0.125 −10.7% PMET 3.22 −4.2% ITH 1.99 −11.6% VMET 12.33 −6.9% ABX 56.41 −5.6% PUR 0.370 +8.8% SCY 0.085 +6.2% AUMN 0.300 +7.1%
Production / Operations

Kalo Gold uses detectORE screening at Vatu Aurum

KALO · Price

Executive Summary

  • Kalo Gold Corp. has adopted the detectORE gold screening system at its Vatu Aurum project in Fiji to enhance drill targeting and accelerate on-site workflow.
  • An internal 2025 validation study of 824 samples demonstrated a strong linear correlation between detectORE units (dU) and certified fire assay gold results, with Pearson correlation coefficients (R) of 0.98 for drill core and 0.96 for trench samples.
  • The technology allows for real-time sample screening to prioritize follow-up and update geological interpretations dynamically, though certified fire assay remains the basis for all reportable drill results under NI 43-101.

Key Details

  • Technology Adoption: Implementation of detectORE, a field-based geochemical technology developed by Portable PPB Pty. Ltd., for rapid on-site gold screening of rock, trench, core, and soil samples.
  • Validation Study Scope: Analysis of 824 total samples, comprising 751 drill core samples and 73 trench samples, selected to cover a range of mineralization styles, gold values, and sample conditions.
  • Correlation Metrics (Pearson R):
    • Total drill core (751 samples): R = 0.98
    • Total trench samples (73 samples): R = 0.96
    • Oxidized samples (364 samples): R = 0.98
    • Fresh/unoxidized samples (348 samples): R = 0.94
  • Methodology:
    • Uses proprietary GLIX-20 reagent system to leach gold from fine-grained samples.
    • Gold is adsorbed onto a proprietary collector device and measured using a calibrated portable X-ray fluorescence analyzer (Evident Vanta, model V2MR).
    • Results reported in detectORE units (dU), a semi-quantitative screening estimate on a part-per-billion-equivalent scale.
  • Quality Assurance:
    • Data tracked and managed through Portable PPB's pLIMS system.
    • Includes real-time monitoring of sample mass, moisture content, and pXRF calibration.
    • Verification via certified reference materials, blanks, duplicates, and calibration collector devices.
    • Batch review and reprocessing triggered by any failure.
  • Reporting Standards:
    • Certified fire assay results remain the basis for reportable drill results under National Instrument 43-101.
    • detectORE data is disclosed as preliminary/supplementary information.
    • dU results are not used to estimate mineral resources or reserves.
  • Qualified Person: Andrew Randell, PGeo, Technical Director, reviewed and approved the technical information.

Notable Quotes

  • "detectORE has materially improved our on-site workflow due to its linear correlation to certified fire assay gold results... It allows our team to screen samples on site in real time and prioritize follow-up while certified laboratory assays are pending." — Terry Tucker, PGeo, CEO of Kalo Gold.
Read the original news release →

More from Kalo Gold Corp.